500T Cross Flow Square Type Water Cooling Tower
video
500T Cross Flow Square Type Water Cooling Tower

500T Cross Flow Square Type Water Cooling Tower

500T Cross Flow Square Type Water Cooling Tower First, what is the cooling tower? A cooling tower is a device in which water and air are in direct contact with each other for heat exchange. The mechanical cooling tower is mainly composed of fans, motors, fillers, water spreading systems, tower...
Send Inquiry
Description

 

500T Cross Flow Square Type Water Cooling Tower


First, what is the cooling tower? A cooling tower is a device in which water and air are in direct contact with each other for heat exchange. The mechanical cooling tower is mainly composed of fans, motors, fillers, water spreading systems, tower bodies, and water pans. The purpose of lowering the water temperature is achieved by the heat exchange between the air with a relatively low temperature and the water in the filler under the action of the fan.


Secondly, how does the cooling tower work?

The cooling method of the cooling tower is to spray hot water on the surface of the heat dissipation material and contact the moving air through it. At this time, heat exchange of sensible heat occurs between the hot water and the cold air, and at the same time, part of the hot water is evaporated, that is, the latent heat of evaporation in the evaporated water vapor is discharged into the air, and finally the cooled water falls into the air. In the water tank, it is sent to the heat exchanger by the pump, and then the heat is absorbed.


Then, we need to know what is wet bulb temperature?

It means that under adiabatic conditions, a large amount of water is in contact with a limited amount of moist air, and the latent heat required for water evaporation comes entirely from the sensible heat released by the decrease in the temperature of the moist air. When the air in the system is saturated and the system reaches thermal equilibrium, the system will temperature. In layman's terms, the wet bulb temperature is the lowest temperature that the current environment can reach only by evaporating water.

Why learn about wet bulb temperature? Because the outlet water temperature of the cooling tower cannot actually be equal to or lower than the wet bulb temperature, in general, the outlet water temperature t2 needs to be higher than the wet bulb temperature by more than 3°C, that is, the approximation degree t2-τ≥3°C. The smaller the approximation, the harder it is to achieve. If the outlet water temperature is to be reduced to the wet bulb temperature, the cooling tower must be infinitely large, which is practically impossible and economical.


Now let's take a look at 500T Cross Flow Square Type Water Cooling Tower's Features:

1. Frame adopt the national standard Tang Gang, high hardness, thick material, load-bearing capacity, surface hot galvanized treatmen.

2. Body casing material, surface layer of plastic used imported wax layer + 33 # gel coat layer, hard and durable, glass steel layer with 889 # resin + boulder fiber, toughness, high hardness, acid

3. All the tower with stainless steel screws, durable and not rust.This is customized part.

4. Exhaust system using high-quality copper core motor and aluminum alloy blade, wear-resistant, high temperature

5. oblique pattern design PVC film to reduce the flow rate, increase the heat transfer area, greatly improve the cooling effect

6. Other: stainless steel float copper valve, nylon cable knot, high temperature corrosion resistance.


Detailed Specs:


Item

Content

Value

Remarks

Basic

specs

Cooling Tower Type

cross flow square type tower


Model

AYD-500L/SB

Low Noise

Circulating Water Flow

500 m3/h


Inlet TempOutlet Temp

3732


DBWB

31.528


Cooling Capacity

2,500,000 kcal/h


Noise Value

66dB(A)


Power Supply

380V3P50Hz


Water Requirement

PH6-8


Design

specs

Air Water Scale

0.81kg/kg


Water resistance

60 Kpa


Flying Water Loss

≤0.001%


Evaporation Loss

0.83%


NetRunning Weight

 3660/7350KG


Motor fan

specs

Fan Type

Axial-Flow


Air Volume

335,000m3/h


RPM

320r/min


Fan DiaΦ

3,400 mm


Quantity of Fan

1set

       4pcs/set

Motor Type

All Closed Water-proof


Driving Mode

Belt


Motor Power

15 kW

       one set

Start Way

Y-


Main

Dimension

L*W*H

6,404,205,800 mm


Inlet Pipe SizeDN

150mm

four set

Outlet Pipe SizeDN

300mm

one set

OverflowDrain PipeDN

80mm80mm

one set each

automanual supplyDN

40mm40mm

one set each

Material

 Orifice

 

Glass Fiber Reinforced Plastics  

Synthesis of high quality glass fiber felt and resin

Sprinkler System

Boarding

Basin, Vat

Belt

Composite Material


Fan

Aluminum Alloy

Big Chord Arc

Motor

All Closed Water Proof

IP55,F class

Film

P.V.C

3000*1230mm

Iron Frame, Motor Frame

hot-dipped galvanized steel

B/T-13912-2002


500T cooling tower


Hot Tags: 500t cross flow square type water cooling tower China, manufacturers, plant, price, for sale

Send Inquiry

(0/10)

clearall