70 Kw Water Chiller With Pump
video
70 Kw Water Chiller With Pump

70 Kw Water Chiller With Pump

A water chiller with an integrated pump efficiently cools and circulates water through a closed-loop system, maintaining precise temperatures for various industrial and commercial applications.
Send Inquiry
Description
ANYDA is well acknowledged as one of the leading manufacturers of 70 kw water chiller with pump in China. All of the products for sale are made in our professional plant. Should you're interested in it, please be free to get the high-tech equipment with competitive price from us.

 

A water chiller with a pump is a cooling system used to regulate the temperature of water in various applications, such as industrial processes, laboratories, aquariums, and even some residential setups.

 

This type of system typically consists of two main components: a chiller unit and a pump.

 

Chiller Unit: The chiller is responsible for cooling the water to the desired temperature. It works by using a refrigeration cycle, similar to how a home air conditioning system operates. The chiller unit contains a compressor, condenser, evaporator, and refrigerant, which work together to remove heat from the water and dissipate it into the surrounding environment. As the water passes through the chiller, it gets cooled down to the set temperature.

 

Pump: The pump is used to circulate the water through the chiller and the system it's cooling. It ensures that water continuously flows through the chiller unit, allowing the heat exchange process to take place. The pump also helps maintain a consistent flow rate and pressure, which is important for efficient cooling.

 

Here's a basic overview of how the water chiller with pump system works:

 

1. Water Circulation: The pump draws water from a reservoir or the application where cooling is needed and circulates it through the chiller unit.

2. Heat Exchange: As the water flows through the chiller's evaporator, heat from the water is absorbed by the refrigerant, causing the water to cool down.

3. Refrigeration Cycle: The refrigerant vaporizes due to the heat absorption and is then compressed by the chiller's compressor. This compression raises the refrigerant's temperature and pressure.

4. Heat Dissipation: The heated refrigerant is condensed in the chiller's condenser, releasing heat into the surrounding environment.

5. Cooling Loop: The now-cooled water is pumped back into the application or reservoir, where it absorbs more heat, starting the cycle anew.

 

The specific design and capacity of a water chiller with pump can vary based on the intended application and cooling requirements. Some systems may include additional features such as temperature controls, sensors, and alarms to ensure precise and reliable cooling.

 

It's important to select a chiller and pump system that matches your cooling needs, taking into account factors like the volume of water to be cooled, the desired temperature range, and any specific requirements of your application. Proper installation, maintenance, and regular checks are essential to ensure the system operates efficiently and effectively.

 

 

70kw Water Chiller with Pump specs:

Item

Specification / Supplier

Cooling capacity

Model

AYD-24W

kw

70

Power input

kw

18.56

Power Supply

380V-3N-50HZ

Temp Outlet (℃)

6-15

refrigerant control

Expansion valve

Refrigeration circle

two

refrigerant

R407C

Dimension(mm)L*W*H

2400*910*1560

Compressor

Style

Scroll

Quantity(set)

2

Compressor Power(kw)

16.36

Condenser

Style

Shell and Tubes

Tower water flow(m3/h)

16

Pipe size(DN)

50

Evaporator

Style

Stainless Steel Plate Heat Exchanger

Cold water flow(m3/h)

12

Pipe size(DN)

40

Stainless Steel Water Pump(kw)

2.2(12m3/h,3bar)

Tank Volume(L)

200

Protector Device

1.Phase protector

2.Fan overload protector

3.High/low voltage protector

4.overheat protector

5.Anti-freeze protector

Unit Weight(kg)

920

Main Parts

Compressor

Sanyo

Condenser

Anyda

Electronic

LS/ Chnt

Expansion Valve

Emerson

Control System

Punp

Remarks: The cooling capacity is based on condensing temp 40C, inlet/outlet temp 12/7C.

 

Company Introduction:

Shen Zhen Anyda Refrigeration Machinery Co., Ltd. is a high-tech private firm that was founded in 2013, with a registered capital of 10 million yuan and a total area of 8900 square metres.
Anyda specialises in industrial refrigeration technology and facilities research, production, and trading. We gradually developed Industrial Chillers, Water Chillers, Air Coolers, Oil Chillers, Low Temperature Chillers, Hot Water Chillers, Heat Pumps, and Central Air Conditioners, which are widely used in plastic and rubber machinery, daily-use chemical, textile, general machinery, laser machinery, LCD and PCB industry, electroplating, laboratory, food, and pharmacy equipment, and so on.

We now have about a hundred employees, with roughly five of them being engineers with 15 years of chiller R&D and production management manufacturing experience, who provide the greatest technical support to our customers.
We have ISO9001:2008 and CE worldwide quality management system certification. We exported to Russia, Uzbekistan, Kazakhstan, Saudi Arabia, Africa, Indonesia, Malaysia, Romania, Bulgaria, Australia, Palestine, Sri Lanka, Mexico, America, Lebanon, and Lithuania, totalling around USD2 million.We look forwards to your idea and are optimistic that we will be your choice!

 

FAQ:

1. How do I maintain an industrial water chiller?

Proper maintenance is crucial to ensure the optimal performance and longevity of your industrial water chiller. Regular maintenance tasks include cleaning or replacing air filters, checking refrigerant levels and pressures, inspecting electrical connections, cleaning condenser coils, lubricating moving parts, and scheduling professional inspections. Consult the manufacturer's guidelines and maintenance manuals for detailed instructions.

 

2. How long does an industrial water chiller typically last?

The lifespan of an industrial water chiller can vary depending on factors such as usage, maintenance practices, and the quality of the equipment. However, with regular maintenance and proper care, an industrial water chiller can last between 15 to 25 years or more.

 

3. Can industrial water chillers be energy-efficient?

A8: Yes, industrial water chillers can be designed to be energy-efficient. Many manufacturers offer chiller models with advanced features such as variable speed drives, energy-efficient compressors, heat recovery options, and intelligent control systems. These features help optimize energy consumption and reduce operating costs.

 

4. Can industrial water chillers be connected to a centralized control system?

A9: Yes, most modern industrial water chillers can be integrated into centralized control systems. This allows for remote monitoring and control of multiple chillers, enabling better management of cooling processes, energy efficiency, and diagnostics.

 

5. What is the HS code of the water chiller?

8418699090.

 

Hot Tags: 70 kw water chiller with pump China, manufacturers, plant, price, for sale

Send Inquiry

(0/10)

clearall