Home > News > Content

What Are The Optimized Maintenance Of Screw Chillers?

Aug 16, 2021

What are the optimized maintenance of screw chillers?


       1. Check the electrical system before starting up


   Check whether the electrical load is required for use; whether the maximum working load of the unit can bear.


   Check whether the main power cord of the unit has a short-circuit switch;


   Confirm that the external wiring is tightly installed, the wiring is correct, and the contact points are free from corrosion, rust, dust accumulation, and other phenomena.


  2. Inspection of compressor and refrigerant piping system


   It should be confirmed that the oil level of the compressor is at a normal value;


   Confirm whether the compressor suction, air stop valve, valve on the pipe, angle valve, ball valve, etc. are open;


   Check the high and low pressure values of the compressor. The lubricating oil preheating time can reach more than 8H.


  3, four items that should be checked for normal operation


   Check whether the water flow conditions of the cold water pump and the cooling water pump meet the requirements;


   Check whether there is any abnormal error on the display;


   There is no abnormal noise or vibration after the unit is running,


   It should be measured whether the operating current of the unit is within the normal range.


  Let’s take a look at the periodic maintenance of the screw chiller:


   4. Pay attention to icing protection


   When the unit is determined to stop running for a long time, the water in the evaporator and condenser should be removed and blown out.


   When the unit is operating in an environment of 0 degrees and below, antifreeze should be added and placed to freeze.


   5. Strict water quality management


  Inspect the cooling water quality to prevent scaling and corrosion of pipes, and regularly check the water quality.


   6. Daily maintenance and management are refined


   When there is sediment and algae in the cooling water of the equipment pipeline, pay attention to maintenance, cleaning, and cleaning, because this will cause the efficiency of the unit to decrease, and the pollution can be solved by the agent or special cleaning fluid. Water quality inspection and analysis should be done every month to use chemical solutions to corrode metal pipes.


  Through the above methods, reasonable operation and maintenance of the screw chiller can be carried out, the service life of the unit can be prolonged, and the high-efficiency refrigeration can be maintained.


Send Inquiry